Air Source Heat Pump Cable Sizing Calculator
Calculate the correct cable size for air source heat pump (ASHP) installations
Boiler Upgrade Scheme Available
MCS-certified installations qualify for the £7,500 Boiler Upgrade Scheme grant in England and Wales. The grant is deducted from your installation cost - no upfront payment required. Check eligibility with your installer.
ASHP Cable Quick Facts
- Most domestic ASHPs need 16A-32A single-phase supply
- Typical cable size: 4mm² or 6mm² depending on run length
- £7,500 Boiler Upgrade Scheme grant available (MCS required)
- Outdoor unit typically within 15m of consumer unit
- Three-phase may be needed for larger 12kW+ systems
Cable Size Calculator
BS 7671:2018+A2:2022 compliant
Need a Qualified Electrician?
Get quotes from vetted, local contractors for your heat pump installation
Common ASHP Installations
5-8kW ASHP (small home)
16A MCB, 2.5mm² or 4mm² cable for runs under 15m
8-12kW ASHP (average home)
20A or 32A MCB, 4mm² or 6mm² cable
12-16kW ASHP (large home)
May need 3-phase supply, consult manufacturer specs
Long cable run to outdoor unit (20m+)
Check voltage drop - likely need 6mm² minimum
ASHP with integrated hot water cylinder
Check total electrical load - may need larger circuit
Complete Your Low-Carbon Home
Heat pumps work brilliantly alongside other renewable technologies. Pair with solar PV and battery storage to power your heat pump with free electricity. Add an EV charger for complete electrification. Heat pump systems often include backup immersion heaters for hot water boosting.
Air Source Heat Pump Cable Sizing
ASHP cable sizing determines the conductor cross-sectional area (mm²) needed to safely supply an air source heat pump. Most domestic ASHPs draw 8-25A depending on size and model. The outdoor unit location and cable run length are critical factors - longer runs need larger cables to maintain voltage within acceptable limits for compressor operation.
ASHP Electrical Installation Costs (2024)
Typical UK electrical installation costs. Does not include heat pump unit or plumbing work.
| Installation Scenario | Materials | Labour | Total |
|---|---|---|---|
| ASHP electrical connection, short run (<10m) | £80-150 | £150-280 | £230-430 |
| ASHP electrical connection, medium run (10-20m) | £150-280 | £200-350 | £350-630 |
| ASHP electrical connection, long run (20m+) | £250-400 | £280-450 | £530-850 |
| Consumer unit upgrade for ASHP | £150-300 | £200-350 | £350-650 |
| Three-phase supply upgrade | £500-1500 | £800-2000 | £1300-3500 |
Prices as of 2024. Three-phase upgrade costs vary significantly by DNO and location.
Boiler Upgrade Scheme (BUS)
The Boiler Upgrade Scheme provides £7,500 grants towards air source heat pump installation in England and Wales. To qualify, the property must have an EPC, and the heat pump must be installed by an MCS-certified installer. The grant is deducted from the installation cost - no upfront payment required from homeowners.
ASHP Electrical Requirements
Air source heat pumps have specific electrical requirements beyond simple cable sizing. These include: inrush current capacity (Type C MCB often needed), voltage stability (±10% tolerance typically), dedicated circuit with appropriate RCD, and local isolator switch. Some units have specific requirements for earth impedance.
Heat Pump COP and Electrical Load
Coefficient of Performance (COP) indicates heat pump efficiency - a COP of 3 means 3kW heat output per 1kW electrical input. This means a 12kW heat output system may only draw 4kW electrically at design conditions. However, COP varies with outdoor temperature, and backup heating may increase electrical load.
Frequently Asked Questions
Related Renewable Energy Calculators
Get Quotes from Local Electricians
Looking for a qualified electrician for your heat pump installation? Tell us about your project and we'll connect you with vetted contractors in your area. Free, no obligation quotes.
Trade professional or electrical business? Use the form above and let us know - we offer lead referrals in your area, bulk calculation tools, and white-label partnerships for merchants and suppliers.
More Electrical Calculators
Voltage drop, conduit fill, earth fault loop impedance and more. All BS 7671 compliant, all free.
View All Calculators